Quick AnswerWhat is Ohm's Law?
Ohm's Law states V=I×RV = I \times R, relating voltage (V), current (I), and resistance (R). Rearrange to find any variable: I=V/RI = V/R for current, R=V/IR = V/I for resistance. For power calculations, use P=V×I=I2R=V2/RP = V \times I = I^2 R = V^2/R.
Example

12V across 6Ω gives I=12/6=2AI = 12/6 = **2A**.

Introduction

Every electrical calculation ultimately derives from Ohm's Law—the fundamental relationship that voltage equals current times resistance. This 200-year-old principle remains the foundation of all circuit analysis, from sizing a simple resistor to designing complex power distribution systems.

Why This Relationship Matters

When current flows through a wire, heat generates according to I²R. When you need to limit current in a circuit, resistance provides the control. When voltage drops across a conductor, Ohm's Law quantifies it. This single equation—V = IR—underlies cable sizing calculations, voltage drop analysis, power dissipation, and protection coordination. Understanding Ohm's Law isn't just academic; it's the prerequisite for practical electrical engineering.

The Fundamental Relationship

Ohm's Law states that voltage across a conductor equals current through it multiplied by its resistance: V = IR. Rearranged, it provides formulas for any unknown: I = V/R for current, R = V/I for resistance. Combined with the power equation P = VI, it yields additional relationships: P = I²R and P = V²/R. These six forms of Ohm's Law and the power equation solve virtually all basic circuit problems.

What You'll Learn

This guide covers Ohm's Law comprehensively, from the basic V = IR relationship through practical applications in circuit design. You'll understand the physical meaning of voltage, current, and resistance, see how temperature affects resistance, and learn when Ohm's Law applies (DC and resistive AC) and when impedance must replace resistance (reactive AC). Worked examples demonstrate real-world calculations for circuit analysis and component selection.

Quick Answer: Ohm's Law Formula

Ohm's Law describes the relationship between voltage, current, and resistance in electrical circuits.

Core Formula

V=I×RV = I \times R

Where:

  • VV = Voltage (volts)
  • II = Current (amperes)
  • RR = Resistance (ohms)

Three Ways to Use Ohm's Law

FindFormulaDescription
VoltageV=I×RV = I \times RMultiply current by resistance
CurrentI=VRI = \frac{V}{R}Divide voltage by resistance
ResistanceR=VIR = \frac{V}{I}Divide voltage by current

Power Formulas

FormulaUse Case
P=V×IP = V \times IFrom voltage and current
P=I2×RP = I^2 \times RFrom current and resistance
P=V2RP = \frac{V^2}{R}From voltage and resistance

Worked Example

230V Circuit with 23Ω Resistance

Given:

  • Voltage: V=230V = 230 V
  • Resistance: R=23ΩR = 23 \Omega

Step 1: Calculate Current

I=23023=10 AI = \frac{230}{23} = 10 \text{ A}

Step 2: Calculate Power

P=230×10=2300W=2.3kWP = 230 \times 10 = 2300\,\text{W} = 2.3\,\text{kW}

Standards Reference

What is Ohm's Law?

Ohm's Law establishes the fundamental relationship between voltage, current, and resistance in electrical circuits. It states that the current flowing through a conductor is directly proportional to the voltage applied across it and inversely proportional to the resistance of the conductor.

This relationship can be expressed mathematically as:

V=I×RV = I \times R

Where:

  • VV = Voltage, the electrical potential difference measured in volts (V)
  • II = Current, the flow of electric charge measured in amperes (A)
  • RR = Resistance, the opposition to current flow measured in ohms (Ω\Omega)

Key Concepts

Voltage (V): Also known as electrical potential difference, voltage is the "pressure" that pushes electric charges through a circuit. It's measured in volts (V). Think of voltage as the electrical equivalent of water pressure in a plumbing system.

Current (I): Current is the flow of electric charges through a conductor. It's measured in amperes (A), often shortened to "amps." Current represents the rate at which charges move through a circuit.

Resistance (R): Resistance is the opposition to the flow of electric current. It's measured in ohms (Ω). Materials with high resistance (like rubber) are insulators, while materials with low resistance (like copper) are conductors.

The Power Triangle

In addition to Ohm's Law, we also use the Power Law to calculate electrical power:

P=V×IP = V \times I

Where PP = Power (in watts, W)

By combining Ohm's Law with the Power Law, we can derive additional formulas:

P=I2×RP=V2R\begin{aligned} P &= I^2 \times R \\ P &= \frac{V^2}{R} \end{aligned}

These formulas are collectively known as the "Power Triangle" and are essential for circuit analysis.

Historical Background

Georg Simon Ohm discovered this relationship in 1827 through careful experimentation with electrical circuits. At the time, his work was controversial and not immediately accepted by the scientific community. However, his findings proved to be accurate and have since become one of the cornerstones of electrical engineering.

Ohm's original formulation was more complex than the modern version, but the fundamental relationship has remained unchanged for nearly 200 years.

Standards and Codes

Ohm's Law is referenced in numerous electrical standards and codes worldwide:

International Standards

  • IEC 60364: International standard for electrical installations in buildings
  • IEC 60028: International standard for copper resistivity
  • IEC 60228: International standard for conductors of insulated cables

National Standards

  • NEC (National Electrical Code): United States standard for safe electrical installations
  • BS 7671: British standard for electrical installations (IET Wiring Regulations)

Understanding the Formula

Basic Relationship

Ohm's Law shows that:

  • If voltage increases, current increases (if resistance stays constant)
  • If resistance increases, current decreases (if voltage stays constant)
  • If current increases, voltage increases (if resistance stays constant)

Rearranging the Formula

The formula can be rearranged to solve for any of the three variables:

To find Voltage:

V=I×RV = I \times R

To find Current:

I=VRI = \frac{V}{R}

To find Resistance:

R=VIR = \frac{V}{I}

Worked Examples

Example 1: Basic Circuit Calculation

Problem: A 230V circuit has a resistance of 23Ω. Calculate the current.

Solution:

Using Ohm's Law:

I=VR=23023=10AI = \frac{V}{R} = \frac{230}{23} = 10\,\text{A}

Answer: The current is 10 amperes.

Example 2: Finding Resistance

Problem: A 12V battery is connected to a circuit that draws 2A of current. What is the circuit resistance?

Solution:

R=VI=122=6ΩR = \frac{V}{I} = \frac{12}{2} = 6\,\Omega

Answer: The resistance is 6 ohms.

Example 3: Calculating Power

Problem: Using the circuit from Example 1, calculate the power consumed.

Solution:

From Example 1: V = 230V, I = 10A

Using the Power Law:

P=V×I=230×10=2300W=2.3kWP = V \times I = 230 \times 10 = 2300\,\text{W} = 2.3\,\text{kW}

Answer: The power consumed is 2.3 kilowatts.

Example 4: LED Circuit

Problem: A 12V LED circuit requires 20mA of current. What resistor is needed?

Solution:

First, convert milliamps to amps: 20mA = 0.02A

R=VI=120.02=600ΩR = \frac{V}{I} = \frac{12}{0.02} = 600\,\Omega

Answer: A 600Ω resistor is required.

Example 5: High-Power Motor

Problem: A 400V motor draws 50A. Calculate the resistance and power.

Solution:

Resistance:

R=VI=40050=8ΩR = \frac{V}{I} = \frac{400}{50} = 8\,\Omega

Power:

P=V×I=400×50=20000W=20kWP = V \times I = 400 \times 50 = 20000\,\text{W} = 20\,\text{kW}

Answer: Resistance is 8Ω and power is 20kW.

Practical Applications

1. Circuit Design

Engineers use Ohm's Law to design circuits that deliver the correct voltage and current to components. This ensures that devices operate within their specifications and prevents damage from overcurrent or overvoltage.

2. Component Selection

When selecting resistors, conductors, and other components, engineers calculate the required resistance values using Ohm's Law. This helps ensure that components are properly sized for the application.

3. Power Supply Sizing

Ohm's Law helps determine the power requirements of electrical systems, which is essential for sizing power supplies, transformers, and other power distribution equipment.

4. Load Calculations

In building electrical systems, Ohm's Law is used to calculate the total load on circuits, which determines the required circuit breaker ratings and conductor sizes.

5. Fault Analysis

When troubleshooting electrical systems, Ohm's Law helps identify where problems occur by comparing expected values with measured values.

Common Mistakes and Pitfalls

Mistake 1: Confusing AC and DC

Ohm's Law applies to DC (direct current) circuits and AC (alternating current) circuits with resistive loads. However, in AC circuits with inductive or capacitive loads, the relationship becomes more complex due to impedance.

Mistake 2: Using Wrong Units

Always ensure that units are consistent:

  • Voltage in volts (V)
  • Current in amperes (A)
  • Resistance in ohms (Ω)

Common errors include forgetting to convert milliamps to amps or kilovolts to volts.

Mistake 3: Assuming Constant Resistance

In real circuits, resistance can vary with temperature. For example, the resistance of a tungsten light bulb filament increases significantly when it heats up.

Mistake 4: Ignoring Power Dissipation

When selecting resistors, consider their power rating. A resistor must be able to dissipate the power calculated by P=I2×RP = I^2 \times R without overheating.

Mistake 5: Not Accounting for Wire Resistance

In long circuits, the resistance of the wires themselves can be significant and should be included in calculations.

Advanced Topics

Temperature Effects on Resistance

Resistance in conductors varies with temperature due to increased atomic vibrations that impede electron flow. The temperature-resistance relationship follows:

RT=R0×[1+α×(TT0)]R_T = R_0 \times [1 + \alpha \times (T - T_0)]

Where:

  • RTR_T = Resistance at operating temperature TT (Ω)
  • R0R_0 = Resistance at reference temperature T0T_0 (Ω)
  • α\alpha = Temperature coefficient of resistance (°C⁻¹)
  • TT = Operating temperature (°C)
  • T0T_0 = Reference temperature, typically 20°C (°C)

Temperature Coefficients (α) at 20°C:

Materialα (×10⁻³ /°C)Application Impact
Copper+3.93Cable resistance increases ~0.4% per °C
Aluminum+3.90Overhead lines: 15-20% resistance increase in summer
Tungsten+4.50Incandescent bulbs: resistance triples when hot
Nichrome+0.40Heating elements: relatively stable
Carbon-0.50Negative coefficient: resistance decreases with temperature

Practical Example: Motor Starting Current

A 10 kW motor with 0.5 Ω winding resistance at 20°C operates at 75°C. Calculate the hot resistance:

R75=0.5×[1+0.00393×(7520)]=0.5×1.216=0.608 ΩR_{75} = 0.5 \times [1 + 0.00393 \times (75 - 20)] = 0.5 \times 1.216 = 0.608 \text{ Ω}

At 230V, cold starting current: Icold=2300.5=460I_{cold} = \frac{230}{0.5} = 460 A At operating temperature: Ihot=2300.608=378I_{hot} = \frac{230}{0.608} = 378 A

The 18% resistance increase reduces steady-state current, but initial inrush current remains high until the motor reaches operating temperature.

Design Considerations:

  • High-current applications: Account for temperature rise in cable sizing. A 100A circuit may require 120A-rated cable to account for resistance increase.
  • Precision measurements: Use temperature-compensated measurements or maintain constant temperature.
  • Thermal cycling: Repeated heating/cooling can cause mechanical stress in connections.

Series Circuit Analysis

In series circuits, current flows through components sequentially. Total resistance equals the sum of individual resistances:

Rtotal=R1+R2+R3++RnR_{total} = R_1 + R_2 + R_3 + \cdots + R_n

Key Characteristics:

  • Current is identical through all components: Itotal=I1=I2=I3I_{total} = I_1 = I_2 = I_3
  • Voltage divides proportionally: Vtotal=V1+V2+V3V_{total} = V_1 + V_2 + V_3
  • Power dissipation: Ptotal=P1+P2+P3=I2(R1+R2+R3)P_{total} = P_1 + P_2 + P_3 = I^2(R_1 + R_2 + R_3)

Example: Voltage Divider Circuit

A 12V source powers two resistors in series: R1=2.2 kΩR_1 = 2.2 \text{ kΩ} and R2=3.3 kΩR_2 = 3.3 \text{ kΩ}.

Rtotal=2.2+3.3=5.5 kΩR_{total} = 2.2 + 3.3 = 5.5 \text{ kΩ} I=125500=2.18 mAI = \frac{12}{5500} = 2.18 \text{ mA} V1=2.18×103×2200=4.8 VV_1 = 2.18 \times 10^{-3} \times 2200 = 4.8 \text{ V} V2=2.18×103×3300=7.2 VV_2 = 2.18 \times 10^{-3} \times 3300 = 7.2 \text{ V}

Engineering Applications:

  • Voltage dividers: Provide reference voltages for sensors and comparators
  • Current limiting: Series resistors protect LEDs and sensitive components
  • Load distribution: Series-connected loads share voltage proportionally

Parallel Circuit Analysis

In parallel circuits, components share the same voltage but current divides. Total resistance is calculated as:

1Rtotal=1R1+1R2+1R3++1Rn\frac{1}{R_{total}} = \frac{1}{R_1} + \frac{1}{R_2} + \frac{1}{R_3} + \cdots + \frac{1}{R_n}

For two resistors: Rtotal=R1×R2R1+R2R_{total} = \frac{R_1 \times R_2}{R_1 + R_2}

Key Characteristics:

  • Voltage is identical across all branches: Vtotal=V1=V2=V3V_{total} = V_1 = V_2 = V_3
  • Current divides inversely with resistance: Itotal=I1+I2+I3I_{total} = I_1 + I_2 + I_3
  • Power dissipation: Ptotal=P1+P2+P3=V2R1+V2R2+V2R3P_{total} = P_1 + P_2 + P_3 = \frac{V^2}{R_1} + \frac{V^2}{R_2} + \frac{V^2}{R_3}

Example: Load Distribution

Three loads connect in parallel to 230V: R1=46 ΩR_1 = 46 \text{ Ω}, R2=92 ΩR_2 = 92 \text{ Ω}, R3=115 ΩR_3 = 115 \text{ Ω}.

1Rtotal=146+192+1115=0.02174+0.01087+0.00870=0.04131\frac{1}{R_{total}} = \frac{1}{46} + \frac{1}{92} + \frac{1}{115} = 0.02174 + 0.01087 + 0.00870 = 0.04131 Rtotal=24.2 ΩR_{total} = 24.2 \text{ Ω} Itotal=23024.2=9.5 AI_{total} = \frac{230}{24.2} = 9.5 \text{ A}

Individual branch currents:

  • I1=23046=5.0 AI_1 = \frac{230}{46} = 5.0 \text{ A} (52.6% of total)
  • I2=23092=2.5 AI_2 = \frac{230}{92} = 2.5 \text{ A} (26.3% of total)
  • I3=230115=2.0 AI_3 = \frac{230}{115} = 2.0 \text{ A} (21.1% of total)

Engineering Applications:

  • Load balancing: Distribute current across multiple paths to reduce individual component stress
  • Redundancy: Parallel paths provide fault tolerance
  • Power distribution: Multiple loads operate independently without affecting each other

AC Circuits and Impedance

Ohm's Law extends to AC circuits using impedance (ZZ) instead of resistance:

V=I×ZV = I \times Z

Impedance combines resistance and reactance:

Z=R2+X2=R2+(XLXC)2Z = \sqrt{R^2 + X^2} = \sqrt{R^2 + (X_L - X_C)^2}

Where:

  • XL=2πfLX_L = 2\pi f L = Inductive reactance (Ω)
  • XC=12πfCX_C = \frac{1}{2\pi f C} = Capacitive reactance (Ω)
  • ff = Frequency (Hz)
  • LL = Inductance (H)
  • CC = Capacitance (F)

Phase Relationship:

Impedance has both magnitude and phase angle:

θ=arctan(XR)\theta = \arctan\left(\frac{X}{R}\right)
  • Resistive load (X=0X = 0): Voltage and current in phase (θ=0°\theta = 0°)
  • Inductive load (XL>XCX_L > X_C): Current lags voltage (θ>0°\theta > 0°)
  • Capacitive load (XC>XLX_C > X_L): Current leads voltage (θ<0°\theta \lt 0°)

Example: AC Motor Circuit

A 230V, 50Hz motor has R=5 ΩR = 5 \text{ Ω} and L=0.05 HL = 0.05 \text{ H}.

XL=2π×50×0.05=15.7 ΩX_L = 2\pi \times 50 \times 0.05 = 15.7 \text{ Ω} Z=52+15.72=16.5 ΩZ = \sqrt{5^2 + 15.7^2} = 16.5 \text{ Ω} I=23016.5=13.9 AI = \frac{230}{16.5} = 13.9 \text{ A} θ=arctan(15.75)=72.3°\theta = \arctan\left(\frac{15.7}{5}\right) = 72.3°

Current lags voltage by 72.3°, requiring power factor correction in many applications.

Non-Linear Resistance

Real-world components often exhibit non-linear resistance, where VI\frac{V}{I} varies with voltage or current.

Semiconductor Diodes:

Forward voltage remains relatively constant (~0.7V for silicon) regardless of current above threshold:

Vdiode0.7 V (for I>Ithreshold)V_{diode} \approx 0.7 \text{ V} \text{ (for } I > I_{threshold} \text{)}

Incandescent Lamps:

Tungsten filament resistance increases dramatically with temperature. A 100W, 230V bulb:

  • Cold resistance: ~50 Ω
  • Hot resistance: ~529 Ω (at operating temperature)

This explains why bulbs often fail when switched on: inrush current is 4-5× normal operating current.

Varistors and Thermistors:

  • Varistors: Resistance decreases with voltage (overvoltage protection)
  • NTC thermistors: Resistance decreases with temperature (temperature sensing)
  • PTC thermistors: Resistance increases with temperature (overcurrent protection)

Modeling Non-Linear Devices:

For small-signal analysis, use incremental resistance:

r=ΔVΔIoperatingpointr = \frac{\Delta V}{\Delta I} \bigg|_{operating point}

This linear approximation works for small variations around the operating point.

Power Dissipation in Complex Circuits

Power calculations become more complex in series-parallel combinations and AC circuits.

DC Power in Series-Parallel Networks:

Calculate equivalent resistance, then apply P=I2RP = I^2 R or P=V2RP = \frac{V^2}{R} based on known quantities.

AC Power (Real Power):

P=VRMS×IRMS×cos(θ)=IRMS2×RP = V_{RMS} \times I_{RMS} \times \cos(\theta) = I_{RMS}^2 \times R

Where cos(θ)\cos(\theta) is the power factor. Only resistance dissipates real power; reactance stores and releases energy but doesn't consume it.

Example: Three-Phase System

A balanced three-phase 400V system supplies 10 kW at 0.85 power factor:

Ptotal=3×Vphase×Iphase×cos(θ)P_{total} = 3 \times V_{phase} \times I_{phase} \times \cos(\theta) Iline=100003×400×0.85=17.0 AI_{line} = \frac{10000}{\sqrt{3} \times 400 \times 0.85} = 17.0 \text{ A}

Each phase carries 17.0 A, but total power is distributed across three phases, reducing individual conductor requirements compared to single-phase.

Practical Engineering Applications

Motor Control:

Variable frequency drives (VFDs) control motor speed by varying frequency, which changes inductive reactance:

XL=2πfLX_L = 2\pi f L

Reducing frequency from 50Hz to 25Hz halves reactance, doubling current for the same voltage. VFDs adjust voltage proportionally to maintain constant current and prevent overheating.

Cable Sizing:

Long cable runs require voltage drop calculations using Ohm's Law:

Vdrop=I×Rcable=I×ρ×LAV_{drop} = I \times R_{cable} = I \times \frac{\rho \times L}{A}

Where ρ\rho is resistivity, LL is length, and AA is cross-sectional area. Maximum acceptable voltage drop is typically 3-5% of supply voltage.

Ground Fault Protection:

Ground fault circuit interrupters (GFCIs) detect current imbalance between line and neutral. Under normal conditions, Iline=IneutralI_{line} = I_{neutral}. A ground fault creates imbalance, triggering protection.

Harmonic Analysis:

Non-linear loads (LED drivers, VFDs, rectifiers) draw non-sinusoidal current. While fundamental frequency follows V=I×ZV = I \times Z, harmonics require separate analysis:

Itotal=I12+I32+I52+I_{total} = \sqrt{I_1^2 + I_3^2 + I_5^2 + \cdots}

Where I1I_1 is fundamental current and I3,I5,I_3, I_5, \ldots are harmonic currents. This increases effective current and heating beyond what fundamental frequency calculations suggest.

Safety

Considerations

Electrical Safety

When working with electrical circuits:

  • Always turn off power before making connections
  • Use appropriate personal protective equipment (PPE)
  • Never exceed component ratings
  • Follow local electrical codes and standards

Power Dissipation

Components that dissipate power generate heat. Ensure adequate cooling and ventilation to prevent overheating and potential fire hazards.

Short Circuits

A short circuit occurs when resistance approaches zero, causing extremely high current. This can damage equipment and create fire hazards. Always use appropriate fuses and circuit breakers.

Using the Calculator

Our Ohm's Law Calculator makes it easy to perform these calculations. Simply enter any two values (voltage, current, or resistance), and the calculator will determine the third value and calculate power.

Calculator Features

  • Calculate voltage, current, or resistance from any two known values
  • Automatically calculate power consumption
  • Support for various units and values
  • Warning system for unusual conditions
  • Professional-grade accuracy

Reference Tables

Common Resistivity Values

MaterialResistivity (Ω·m at 20°C)Use Case
Silver1.59×1081.59 \times 10^{-8}Best conductor (expensive)
Copper1.68×1081.68 \times 10^{-8}Standard electrical wiring
Aluminum2.65×1082.65 \times 10^{-8}Power transmission lines
Iron9.71×1089.71 \times 10^{-8}Electrical appliances
Carbon3.5×1053.5 \times 10^{-5}Resistors

Common Voltage Standards

StandardVoltageRegion
Low Voltage230VEurope, most of world
Low Voltage120VNorth America
Medium Voltage400VIndustrial (Europe)
Medium Voltage208VIndustrial (North America)
High Voltage1000V+Power transmission

Typical Current Ratings

ApplicationTypical Current
LED10-50 mA
Small appliance1-5 A
Residential circuit16-32 A
Commercial circuit32-100 A
Industrial motor50-500 A

Further Reading

Our calculations follow industry best practices and have been validated against real-world scenarios.

Conclusion

Ohm's Law is a fundamental principle that every electrical engineer and technician must understand. It provides the foundation for analyzing and designing electrical circuits, from simple LED circuits to complex power distribution systems. By mastering Ohm's Law and the related power formulas, you gain the ability to design safe and efficient electrical circuits, troubleshoot electrical problems, select appropriate components, and understand how electrical systems work. Remember, while Ohm's Law is simple in concept, its applications are vast and varied—practice with different scenarios, use calculators to verify your work, and always prioritize safety when working with electrical systems.

Export as PDF — Generate professional reports for documentation, client presentations, or permit submissions.


Key Takeaways

  • Ohm's Law formula V=I×RV = I \times R describes the fundamental relationship between voltage, current, and resistance in electrical circuits
  • The formula can be rearranged to solve for any variable: I=V/RI = V/R for current, R=V/IR = V/I for resistance
  • Ohm's Law applies to DC circuits and AC circuits with purely resistive loads; for AC with inductive/capacitive loads, use impedance (Z) instead
  • Power calculations use related formulas: P=V×IP = V \times I, P=I2×RP = I^2 \times R, or P=V2/RP = V^2/R
  • Resistance increases with temperature for most conductors, requiring temperature correction in high-current applications
  • Always verify calculations, ensure units are consistent, and check that results are reasonable for the application

Further Learning

References & Standards

This guide follows established engineering principles and standards. For detailed requirements, always consult the current adopted edition in your jurisdiction.

Primary Standards

IEC 60364-5-52:2009 Low-voltage electrical installations - Part 5-52: Selection and erection of electrical equipment - Wiring systems.

National Electrical Code (NEC) 2023 NFPA 70 - Comprehensive electrical safety standards for the United States.

BS 7671:2018+A2:2022 Requirements for Electrical Installations - IET Wiring Regulations.

Supporting Standards & Guidelines

IEC 60028:1925 International standard of resistance for copper.

Further Reading

Note: Standards and codes are regularly updated. Always verify you're using the current adopted edition applicable to your project's location. Consult with local authorities having jurisdiction (AHJ) for specific requirements.


Disclaimer: This guide provides general technical information based on international electrical standards. Always verify calculations with applicable local electrical codes (NEC, IEC, BS 7671, etc.) and consult licensed electrical engineers or electricians for actual installations. Electrical work should only be performed by qualified professionals. Component ratings and specifications may vary by manufacturer.

Frequently Asked Questions

Ohm's Law Guide | Enginist